The Symphony Diet 12T 12-litre Personal Air Cooler is a compact, powerful, and energy-efficient air-cooling solution for your home. It features i-Pure Technology, which purifies the air while cooling it, and a Cool Flow Dispenser, which enhances its cooling performance. The 12-litre tank capacity reduces the need for frequent refills, and its four castor wheels make it easy to move across different floors. The Diet 12T's control panel is designed for ease of use, with smooth-turning knobs for power, fan speed, cooling mode, and swing, allowing you to customise your cooling experience.

Characteristics Values
Air Throw 30ft or 81 sq. m
Tank Capacity 12 litres
Cooling Pads Honeycomb
Ice Chamber Yes
Speed Variations 3
Cooling Modes 2
Louvres 4-Way Swing
Filters Dust, PM2.5 wash, allergy, bacteria, smell
Wheels 4 Castor Wheels
Voltage Protection SMPS Technology
Colour White
Technology i-Pure Technology
Energy Efficiency Low Power Consumption

shunketo

Setting up the Symphony Diet 12T Air Cooler

  • Unbox and Position the Air Cooler: Start by carefully unboxing the Symphony Diet 12T Air Cooler. Place it on a flat, stable surface in the desired location. The unit is equipped with four durable castor wheels, allowing you to move it effortlessly across different floors and areas of your space.
  • Water Tank Preparation: The Symphony Diet 12T boasts a 12-litre water tank capacity. Fill the tank with water to ensure long-lasting operation and reduced refills. You can also add ice cubes or gel packs to the ice chamber for an even cooler experience. The water level indicator will help you monitor the water level in the tank.
  • Adjust Settings: The Symphony Diet 12T features a user-friendly control panel with knob controls. Adjust the settings according to your preference, including power, fan speed, cooling mode, and swing. The knobs offer precise control, ensuring a customisable and comfortable cooling experience.
  • Direction of Airflow: This air cooler provides versatile airflow control. You can adjust the louvres in four directions to direct the cool air to specific areas or create an oscillating effect for overall cooling.
  • Filter Maintenance: The air cooler is equipped with reliable filters, including a dust filter, PM2.5 wash filter, allergy filter, bacteria filter, and smell filter. Ensure that these filters are properly installed and maintained for effective removal of dust, allergens, germs, and airborne particles.
  • Safety Features: The Symphony Diet 12T incorporates SMPS technology for voltage protection. This feature ensures your safety by promptly shutting off the unit during voltage fluctuations or electrical surges.
  • Test and Enjoy: Once you've completed the initial setup, turn on the air cooler and enjoy the refreshing breeze. The powerful blower and honeycomb pads ensure efficient and consistent cooling performance.

Remember to refer to the user manual for detailed instructions and safety guidelines specific to your Symphony Diet 12T Air Cooler.

shunketo

Using the control panel

The Symphony Diet 12T Personal Tower Air Cooler is designed for ease of use, with a control panel featuring ergonomic dial knobs for precise control over various settings. The control panel has smooth-turning knobs that allow you to adjust the power, fan speed, cooling mode, and swing settings. Each knob offers customizability and comfort, ensuring a seamless cooling experience.

The power knob lets you turn the unit on or off, while the fan speed knob allows you to adjust the airflow intensity, with three-speed variations to choose from. You can also select from two available cooling modes to dial down or increase the cooling intensity as needed.

Additionally, the swing knob lets you control the direction of the airflow. With a four-way swing function, you can adjust the louvres in four directions to direct the cool air to specific areas or create an oscillating effect for overall room cooling. This feature provides versatile airflow control, catering to your specific preferences and cooling requirements.

The control panel's intuitive knob controls make it effortless to operate the air cooler. The ergonomic design of the knobs not only facilitates ease of use but also contributes to the elegant and modern look of the Symphony Diet 12T Personal Tower Air Cooler.

shunketo

Adjusting the louvres

The Symphony Diet 12T air cooler features four-way swing functionality, enabling you to adjust the louvres in four directions. This gives you the flexibility to personalise the airflow direction based on your specific needs.

To adjust the louvres, locate the control knobs on the air cooler. These knobs are designed to be intuitive and easy to use. You can use the knobs to set the louvres to your desired position, whether directing the airflow to a particular spot or achieving a widespread cooling effect.

Additionally, the Symphony Diet 12T air cooler offers auto-louvre movement. This feature allows the louvres to move automatically, providing a dynamic and hands-free airflow adjustment. With the auto-louvre movement, the air cooler can create a more consistent and evenly distributed cooling experience in the room.

shunketo

Maintaining and refilling the water tank

Maintaining the Water Tank:

  • Check the water level regularly: The Symphony Diet 12T boasts a 12-litre water tank, which provides long-lasting operation. Keep an eye on the water level indicator to ensure the tank doesn't run dry.
  • Refill as needed: Depending on usage, you may need to refill the tank once or twice a day. Always refill the tank before it runs out of water to ensure uninterrupted cooling.
  • Clean the tank periodically: It is important to clean the water tank regularly to prevent the buildup of dirt, dust, or bacteria. Refer to the user manual for specific cleaning instructions.
  • Check for leaks: Some users have reported issues with water leakage. Inspect the unit regularly for any signs of leakage and contact customer support if needed.

Refilling the Water Tank:

  • Locate the water tank: The Symphony Diet 12T has a compact design, so the water tank is easily accessible.
  • Remove the water tank: Gently pull out the water tank from its compartment. Most portable air coolers have a removable water tank for easy refilling.
  • Refill with clean water: Fill the tank with clean, fresh water. You can also add ice cubes or gel packs to the ice chamber for an extra cooling boost.
  • Securely replace the water tank: After refilling, put the water tank back into its compartment. Ensure it is properly secured and aligned.
  • Adjust settings as needed: Depending on your preference, you can adjust the fan speed, cooling mode, and swing settings after refilling to customise your cooling experience.

By following these steps, you can effectively maintain and refill the water tank of your Symphony Diet 12T air cooler, ensuring optimal performance and a comfortable environment. Remember to refer to the user manual for additional instructions and care tips specific to your unit.

shunketo

Troubleshooting

Water Leakage

Some customers have reported issues with water leakage from the unit, which can cause water to drip through the holes and overflow. To address this, ensure the unit is placed on a level surface and check for any blockages or damage to the water pipes and pumps.

Noise

The Symphony Diet 12T operates quietly, but if you notice excessive noise, check that the unit is stable and that all components are secure. Noise may also be due to a build-up of dust or debris, so regular cleaning and maintenance are important.

Odour

A strange odour coming from the air cooler may be due to stagnant water or mildew growth on the pads. Regularly change the water and clean the cooling pads to prevent this issue. To clean the pads, unplug the unit and use a low-pressure water pipe to clean the pad from the outside. Aim to clean the pads at least once or twice a year.

Performance

If the air cooler is not performing as expected, check the humidity levels in the room, as the unit may struggle to cool effectively in high humidity. Also, ensure the unit is the appropriate size for the room, as very large rooms may require a more heavy-duty cooler.

Maintenance

To ensure the longevity of your Symphony Diet 12T, regular maintenance is important. Clean the unit regularly, including the honeycomb pads, and keep the water tank filled with clean water. Check all components for any signs of damage or wear and promptly address any issues.

Frequently asked questions

The Symphony Diet 12T Air Cooler is designed to be easy to use. It features a control panel with smooth-turning knobs for power, fan speed, cooling mode, and swing. The cooler also has four durable castor wheels, allowing you to move it effortlessly across different floors and areas of your space.

The Symphony Diet 12T Air Cooler has a 12-litre tank capacity, providing long-lasting operation and reducing the need for frequent refills. It offers three-speed variations and two cooling modes, allowing you to customise the cooling according to your preferences. The cooler also features a dust filter, PM2.5 wash filter, allergy filter, bacteria filter, and smell filter, ensuring a cleaner and healthier home.

The Symphony Diet 12T Air Cooler uses a powerful blower and i-Pure Technology to deliver a refreshing breeze and effective cooling. The i-Pure Technology purifies the air, reducing dust, allergens, and other impurities, making the atmosphere fresher and healthier.

It is important to regularly clean and maintain the Symphony Diet 12T Air Cooler for optimal performance. Refer to the user manual for specific instructions. Some general care tips include regularly checking and cleaning the water tank, ensuring proper ventilation in the room, and periodically cleaning or replacing the air filters.

The Symphony Diet 12T Air Cooler offers a compact and elegant design, making it ideal for personal cooling while taking up minimal space. It provides efficient and tailored cooling, allowing you to customise the direction of airflow with its four-way swing feature. The cooler also prioritises safety with SMPS technology, which promptly shuts off the unit during voltage fluctuations or electrical surges.

Written by
Reviewed by
Share this post
Print
Did this article help you?

Leave a comment